VX-1200 |
VX-2400 |
| Load Capability |
12 Channel
1.2KW Per Channel
14.4KW Total |
12 Channel
2.4KW Per Channel
28.8KW Total |
| Power Input (Term Lug) |
105-124VAC 60HZ
240VAC Available |
105-124VAC 60HZ
240VAC Available |
| Three Phase |
Three 40 Amp Circuits |
Three 80 Amp Circuits |
Three Phase/Single Phase
(Selectable)
(Stage Pin/U-Ground) |
Three 40 Amp Circuits
Two 60 Amp Circuits |
Three 80 Amp Circuits
Two 120 Amp Circuits |
| DMX-512 (In-Out) |
5 Pin XLR Connector |
5 Pin XLR Connector |
| Analog Input (8 CJC 2 each) |
Input Impedance-200K ohm |
Input Impedance-200K ohm |
| Analog Control Range |
Maximum +5 to 24 Volts |
Maximum +5 to 24 Volts |
| Cooling |
100% Duty Cycle |
100% Duty Cycle |
| Minimum Load (for Proper
Function) |
15 Watts Per Channel |
15 Watts Per Channel |
| Full On Test Switch |
Locking |
Locking |
| Front Accessible Power Devices |
12 Removable SCR modules |
12 Removable SCR modules |
| Magnetic Circuit Breakers (per
Channel) |
10 Amp Breaker |
20 Amp Breaker |
| Overvoltage Protection |
yes |
yes |
| Overtemp Protection |
LED Indication |
LED Indication |
| Snapshot Memories |
10 |
10 |
| Curve |
Within 5% of “Square Law” |
Within 5% of “Square Law” |
| Filtering-Rise Time |
350 Microseconds |
400 Microseconds |
| Output Range |
97.5% of Line Voltage |
97.5% of Line Voltage |
| Output Indicator (per Channel) |
LED |
LED |
| No Load Indicator (per Channel) |
LED |
LED |
| Conduction Angle Range |
0-180° |
0-180° |
| RBVX-Kit Front and Rear Brace
Kit |
yes |
yes |
| SAVX-Kit Stand Alone Kit |
Optional |
Optional |
| UL Listed |
yes |
yes |
| cUL Listed |
yes |
yes |
Height, Width, Depth in inches
(E.I.A. 19” Standard Rack Mount) |
7 x 19 x 17 |
7 x 19 x 17 |
| Net Weight-lbs |
50 |
54 |
Load Panel Options
(Choose one) |
ULX U Ground outlets, 2
per channel (24 total) (VX-1200, VX-2400 only)  |
|
SPX Socapex load (24 circuits) with
Powerlock Patchbay, Wire power input. Stand alone or rack mount. |
|
|
SLX 20 Amp Harj-Lock
stage pin connectors, 2 per channel (24 total).
(VX-1200, VX-2400 only.)  |
| |
TLX Rear accessible
terminal strip. Three barrier strips allow 12 circuits of 20 amps each.
(VX-1200, VX-2400 only.) Specify single phase or three phase .
|
| |
PLX Patchbay Powerlock
load panel with four Amp Powerlock connectors per channel (48 total). (All
VX models.) .
|